We’re the highest rated data center in Houston

The Difference

Compare our Specs

Our facility uniquely features cutting-edge capabilities such as waterless cooling, indoor generators, and infinite fuel sources to provide the highest level of convenience, reliability and uptime for our clients. See our comparison table for yourself.

TRG Datacenters

Stream

Size
Size
150,000 Sq Ft
Size
30,000 Sq Ft
Remote Hands On
Remote Hands On
Free 24/7, with emergency availability with 15 mins response time
Remote Hands On
Additional cost
Hours of Operation
Hours of Operation
24/7
Hours of Operation
Unknown
Reviews (on Google)
Reviews (on Google)
89 5-stars
Reviews (on Google)
7 4.6-stars
SLA
SLA
100% uptime guarantee, with 100% of your month free for portion of services affected by ANY downtime
SLA
100% Uptime since 2013
Floodplain
Floodplain
Outside of the 500-year floodplain, and we then still built 3 feet above ground level
Floodplain
Outside 500 year flood plain
Hurricane Resistance
Hurricane Resistance
With a single sloped roof, with 2 layers of leak protection including a concrete deck. It’s rated for 185+ MPH
Hurricane Resistance
Spec built facility
Location
Location
Near both the I-45 and I-99 making it highly accessible by any part of Houston, but with our Colo+ service you never have to visit anyway.
Location
In The Woodlands, Texas
Power
Power
Four different substations in the area supplying power, owned medium voltage infrastructure with spare parts. Critical Load designation from CentrePoint Energy ensures priority restoration in the event of any outage.
Power
Underground utility power feeds
Batteries / UPS
Batteries / UPS
Pure lead batteries deployed in 2(N+1) reliability configuration, achieving published performance for ultra-fast discharge. Multiple redundant and fault tolerant compartmentalized units. We use Toshiba G9000s for category defining efficiency and achieving fault tolerance
Batteries / UPS
2N distribution to the rack with legacy 5 min rated battery design
Stock Parts
Stock Parts
On-site replacement parts for every system in case they are needed
Stock Parts
Some tools, but limited to no parts provided

Location
Location
Indoor, significantly more reliable than outdoor
Location
Outdoor, which makes them susceptible to weather damage and harder to maintain during summer reducing their reliability
Specification
Specification
Multiple 1.5 MVA Rolls Royce MTU V18 Twin Turbo Systems with hurricane resistant louver systems
Specification
Unknown
Fuel supplies
Fuel supplies
Independent and isolated fuel reserves lasting 4+ days, and the option for natural gas bi-fuel extending runtime to 12+ days without re-fueling
Fuel supplies
Unknown
Emergency Fuel
Emergency Fuel
Emergency backup contracts for infinite fuel resupply
Emergency Fuel
Unknown
Time to generator
Time to generator
Less than 10 seconds and meets NFPA 110 requirements
Time to generator
Less than 30 seconds

Water
Water
100% waterless facility, so no risk of water distribution inside facility and are more environmentally friendly
Water
Concurrently maintainable chiller loop in data halls, which is a single point of failure per Uptime Institute tier standards.
High Performance Computing
High Performance Computing
Fully modular, compartmentalized cooling enables 50kW cabinets and blade server environments or more
High Performance Computing
Support for high density deployments

Cross Connects
Cross Connects
Free, forever, always
Cross Connects
Additional cost
Carriers
Carriers
15+ and free entry for any you want to bring
Carriers
Unknown
Redundant Infrastructure
Redundant Infrastructure
Truly redundant, compartmentalized and fault tolerant
Redundant Infrastructure
Tier III Design
Meet Me Rooms
Meet Me Rooms
Dual entries into dual meet me rooms
Meet Me Rooms
Single meet me room
Cabling
Cabling
Milspec armored core fiber cabling with corning high bend radius glass for ultra reliability
Cabling
Standard non-armored cabling

Team history
Team history
FISMA compliant. Experience working with Department of Defense, MIT Lincoln Lab & the CIA
Team history
Outsourced unarmed guards
Fiver layers of security
Fiver layers of security
Fiver layers of security
Customizable
Customizable
Fully customizable cabinet and suite security for example; motion sensors, man traps and armed security guards
Customizable
Local area crime rate
Local area crime rate
#1 City to live in America in 2022
Local area crime rate
Unknown

HIPAA
HIPAA
HIPAA
Unknown
SSAE
SSAE
SSAE
Unknown
SOC
SOC
SOC
Unknown
PCI
PCI
PCI
Unknown
NFPA 110
NFPA 110
NFPA 110
Unknown

Offices
Offices
30+ over-sized offices (11×13 sq. ft) available for rent so you can build your own NOC
Offices
Unknown
Conference Rooms
Conference Rooms
Multiple executive conference rooms
Conference Rooms
Unknown
Breakout Rooms
Breakout Rooms
Breakout Rooms
Unknown
Showers
Showers
Showers
Unknown
Wifi Throughout
Wifi Throughout
Wifi Throughout
Unknown

Johnny Greene @ Millennium Physicians

"When they give you their word they back it up. Everything you need... is here. They do things completely different than other data centers"

Why choose us

Free Cross Connects

Ordering a cross connect at TRG is as simple as kicking a ticket in. No contracts needed.

We offer these free, forever for all our customers.

13+ Onsite Carriers

Why choose us

Free Remote Hands On

We offer a non-emergency, non-SLA’d “best effort” free remote hands-on tier that is entirely free.

We also offer an SLA’d emergency ticket queue, but have had ZERO emergencies over the last year.